Quiz Summary
0 of 20 Questions completed
Questions:
Information
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading…
You must sign in or sign up to start the quiz.
You must first complete the following:
Results
Results
0 of 20 Questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 point(s), (0)
Earned Point(s): 0 of 0, (0)
0 Essay(s) Pending (Possible Point(s): 0)
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
- Current
- Review
- Answered
- Correct
- Incorrect
- Question 1 of 20
1. Question
Although there may be other reasons for using calcium tungstate screens in industrial radiography, they are most usually used to:
CorrectIncorrect - Question 2 of 20
2. Question
An excellent radiograph is obtained under given exposure conditions with a tube current of 5 mA and an exposure time of 12 minutes. If other conditions are not changed, what exposure time would be required if the X-ray tube current could be raised to 10 mA?
CorrectIncorrect - Question 3 of 20
3. Question
In film radiography, penetrameters are usually placed:
CorrectIncorrect - Question 4 of 20
4. Question
A densitometer is an instrument for measuring:
CorrectIncorrect - Question 5 of 20
5. Question
The two most common causes for excessively high-density radiographs are:
CorrectIncorrect - Question 6 of 20
6. Question
When doing gamma ray radiography with high-intensity emitters, the sources are best handled:
CorrectIncorrect - Question 7 of 20
7. Question
Lead foil in direct contact with X-ray film:
CorrectIncorrect - Question 8 of 20
8. Question
Fluorescent intensifying screens are usually mounted in pairs in rigid holders called:
CorrectIncorrect - Question 9 of 20
9. Question
Which of the following materials is suitable for use in vessels or pails and used to mix processing solutions?
CorrectIncorrect - Question 10 of 20
10. Question
Of the following, which would be especially sensitive to injury by excessive exposure to X or gamma rays?
CorrectIncorrect - Question 11 of 20
11. Question
A penetrameter is used to indicate the:
CorrectIncorrect - Question 12 of 20
12. Question
A fluorescent intensifying screen will:
CorrectIncorrect - Question 13 of 20
13. Question
Static marks, which are black tree-like or circular marks on a radiograph, are often caused by
CorrectIncorrect - Question 14 of 20
14. Question
The purpose of agitating an X-ray film during development is to:
CorrectIncorrect - Question 15 of 20
15. Question
The exposure of personnel to X- and gamma radiation can be measured or monitored by means of:
CorrectIncorrect - Question 16 of 20
16. Question
Assuming that a good radiograph is obtained at a setting of 10 mA in 40 s, how much time will be necessary to obtain one equivalent radiograph if the milliamperage is changed to 5 mA (all other conditions remaining constant) ?
CorrectIncorrect - Question 17 of 20
17. Question
Why is Co-60 used as radiation source for medium-weight metals of thickness ranges from 38 to 229 mm (1.5 to 9 inches)?
CorrectIncorrect - Question 18 of 20
18. Question
During manual film processing, the purpose of the stop bath is:
CorrectIncorrect - Question 19 of 20
19. Question
What is sometimes used to change the alternating current from the high voltage transformer to direct current for the purpose of increasing the X-ray machine output?
CorrectIncorrect - Question 20 of 20
20. Question
Approximately, what percent of the original radioactivity is left after 6 half-lives?
CorrectIncorrect