Skip to content
APEX-FI Logo
  • About us
  • Training
    • Conventional Non-Destructive Testing Courses
    • Advanced Non-Destructive Testing Courses
    • Cours de contrôle non destructif
    • API preparatory Training
    • Training registration
  • Services
    • NDT Inspection
      • Conventional Non-Destructive Testing
      • Advanced Non-Destructive Testing
      • Supplementary Non-Destructive Examination
    • Inspection Solutions
    • Inspection Consultancy
    • Asset Integrity Solutions
    • NDT Products
      • NDT Equipment
      • Calibration Blocks
      • Probes and Scanners
  • Certifications
    • Policies
    • Documentations
    • Certificate Holders
    • Complaints & Appeals
    • Get Certified
  • Contact us
  • About us
  • Training
    • Conventional Non-Destructive Testing Courses
    • Advanced Non-Destructive Testing Courses
    • Cours de contrôle non destructif
    • API preparatory Training
    • Training registration
  • Services
    • NDT Inspection
      • Conventional Non-Destructive Testing
      • Advanced Non-Destructive Testing
      • Supplementary Non-Destructive Examination
    • Inspection Solutions
    • Inspection Consultancy
    • Asset Integrity Solutions
    • NDT Products
      • NDT Equipment
      • Calibration Blocks
      • Probes and Scanners
  • Certifications
    • Policies
    • Documentations
    • Certificate Holders
    • Complaints & Appeals
    • Get Certified
  • Contact us
  • About us
  • Training
    • Conventional Non-Destructive Testing Courses
    • Advanced Non-Destructive Testing Courses
    • Cours de contrôle non destructif
    • API preparatory Training
    • Training registration
  • Services
    • NDT Inspection
      • Conventional Non-Destructive Testing
      • Advanced Non-Destructive Testing
      • Supplementary Non-Destructive Examination
    • Inspection Solutions
    • Inspection Consultancy
    • Asset Integrity Solutions
    • NDT Products
      • NDT Equipment
      • Calibration Blocks
      • Probes and Scanners
  • Certifications
    • Policies
    • Documentations
    • Certificate Holders
    • Complaints & Appeals
    • Get Certified
  • Contact us
E7-UT-G-2
Time limit: 0

Quiz Summary

0 of 40 Questions completed

Questions:

Information

You have already completed the quiz before. Hence you can not start it again.

Quiz is loading…

You must sign in or sign up to start the quiz.

You must first complete the following:

Results

Quiz complete. Results are being recorded.

Results

0 of 40 Questions answered correctly

Your time:

Time has elapsed

You have reached 0 of 0 point(s), (0)

Earned Point(s): 0 of 0, (0)
0 Essay(s) Pending (Possible Point(s): 0)

Categories

  1. Not categorized 0%
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5
  6. 6
  7. 7
  8. 8
  9. 9
  10. 10
  11. 11
  12. 12
  13. 13
  14. 14
  15. 15
  16. 16
  17. 17
  18. 18
  19. 19
  20. 20
  21. 21
  22. 22
  23. 23
  24. 24
  25. 25
  26. 26
  27. 27
  28. 28
  29. 29
  30. 30
  31. 31
  32. 32
  33. 33
  34. 34
  35. 35
  36. 36
  37. 37
  38. 38
  39. 39
  40. 40
  1. Current
  2. Review
  3. Answered
  4. Correct
  5. Incorrect
  1. Question 1 of 40
    1. Question

    The only significant sound wave mode that travels through a liquid is a:

    Correct
    Incorrect
  2. Question 2 of 40
    2. Question

    The acoustic impedance of a material is used to determine the:

    Correct
    Incorrect
  3. Question 3 of 40
    3. Question

    When angle beam contact testing a test piece, increasing the incident angle until the second critical angle is reached results in:

    Correct
    Incorrect
  4. Question 4 of 40
    4. Question

    The random distribution of crystallographic direction in alloys with large crystalline structures is a factor in determining:

    Correct
    Incorrect
  5. Question 5 of 40
    5. Question

    The length of the zone adjacent to a transducer in which fluctuations in sound pressure occur is mostly affected by:

    Correct
    Incorrect
  6. Question 6 of 40
    6. Question

    The differences in signals received from identical reflectors at different material distances from a transducer may be caused by:

    Correct
    Incorrect
  7. Question 7 of 40
    7. Question

    In the far field of a uniform ultrasonic beam, sound intensity is ___________ the beam centerline.

    Correct
    Incorrect
  8. Question 8 of 40
    8. Question

    As the radius of curvature of a curved lens is increased, the focal length of the lens:

    Correct
    Incorrect
  9. Question 9 of 40
    9. Question

    Rayleigh waves are influenced most by defects located:

    Correct
    Incorrect
  10. Question 10 of 40
    10. Question

    The ultrasonic testing technique in which finger damping is most effective in locating a discontinuity is the:

    Correct
    Incorrect
  11. Question 11 of 40
    11. Question

    At an interface between two different materials, an impedance difference results in:

    Correct
    Incorrect
  12. Question 12 of 40
    12. Question

    In the immersion technique, the distance between the face of the transducer and the test surface (water path) is usually adjusted so that the time required to send the sound beam through the water:

    Correct
    Incorrect
  13. Question 13 of 40
    13. Question

    On an A-scan display, the “dead zone,” refers to:

    Correct
    Incorrect
  14. Question 14 of 40
    14. Question

    In straight (normal) beam contact testing, a reduction in the back surface reflection amplitude could indicate:

    Correct
    Incorrect
  15. Question 15 of 40
    15. Question

    A primary purpose of a reference standard is:

    Correct
    Incorrect
  16. Question 16 of 40
    16. Question

    Compensation for the variation in echo height related to variations in discontinuity depth in the test material is known as:

    Correct
    Incorrect
  17. Question 17 of 40
    17. Question

    Which of the following is a reference reflector that is not dependent on beam angle?

    Correct
    Incorrect
  18. Question 18 of 40
    18. Question

    The angle at which 90 degrees refraction of a longitudinal sound wave is reached is called:

    Correct
    Incorrect
  19. Question 19 of 40
    19. Question

    Attenuation is a difficult quantity to measure accurately, particularly in solid materials, at the test frequencies normally used. The overall result usually observed includes other loss mechanisms which can include:

    Correct
    Incorrect
  20. Question 20 of 40
    20. Question

    The vertical linear range of a test instrument may be determined by obtaining ultrasonic responses from:

    Correct
    Incorrect
  21. Question 21 of 40
    21. Question

    Large grains in a metallic test specimen usually result in:

    Correct
    Incorrect
  22. Question 22 of 40
    22. Question

    The angle formed by an ultrasonic wave as it enters a medium of different velocity than the one from which it came and a line drawn perpendicular to the interface between the two media is called the angle of:

    Correct
    Incorrect
  23. Question 23 of 40
    23. Question

    The process of adjusting an instrument or device to a reference standard is referred to as:

    Correct
    Incorrect
  24. Question 24 of 40
    24. Question

    An electron tube in which a beam of electrons from the cathode is used to reproduce an image on a display at the end of the tube is referred to as:

    Correct
    Incorrect
  25. Question 25 of 40
    25. Question

    A grouping of a number of crystals in one transducer, with all contact surfaces in the same plane, and vibrating in phase with each other to act as a single transducer is called a:

    Correct
    Incorrect
  26. Question 26 of 40
    26. Question

    The angle of reflection is

    Correct
    Incorrect
  27. Question 27 of 40
    27. Question

    The change in direction of an ultrasonic beam when it passes from one medium to another whose velocity differs from that of the first medium is called:

    Correct
    Incorrect
  28. Question 28 of 40
    28. Question

    Which of the following modes of vibration exhibits the shortest wavelength at a given frequency and in a given material?

    Correct
    Incorrect
  29. Question 29 of 40
    29. Question

    In general, shear waves are more sensitive to small discontinuities than longitudinal waves for a given frequency and in a given material because:

    Correct
    Incorrect
  30. Question 30 of 40
    30. Question

    The speed with which ultrasonic waves travel through a material is known as its

    Correct
    Incorrect
  31. Question 31 of 40
    31. Question

    A substance that reduces the surface tension of a liquid is referred to as:

    Correct
    Incorrect
  32. Question 32 of 40
    32. Question

    The ultrasonic transducers most commonly used for discontinuity testing utilize:

    Correct
    Incorrect
  33. Question 33 of 40
    33. Question

    Mechanical and electrical stability, insolubility in liquids, and resistance to aging are three advantages of transducers made of:

    Correct
    Incorrect
  34. Question 34 of 40
    34. Question

    The formula sin θ1/V1 = sin θ2/V2 is used to determine:

    Correct
    Incorrect
  35. Question 35 of 40
    35. Question

    The amount of energy reflected from a discontinuity is dependent on:

    Correct
    Incorrect
  36. Question 36 of 40
    36. Question

    Which of the following frequencies would probably result in the greatest ultrasonic attenuation losses?

    Correct
    Incorrect
  37. Question 37 of 40
    37. Question

    The product of the sound velocity and the density of a material is known as the:

    Correct
    Incorrect
  38. Question 38 of 40
    38. Question

    The amplifier range over which the unsaturated signal response increases in amplitude in proportion to the discontinuity surface area is the

    Correct
    Incorrect
  39. Question 39 of 40
    39. Question

    Significant errors in ultrasonic thickness measurement can occur if:

    Correct
    Incorrect
  40. Question 40 of 40
    40. Question

    An ultrasonic testing instrument that displays pulses representing the magnitude of reflected ultrasound as a function of time or depth of metal is said to contain:

    Correct
    Incorrect
Comments Off on E7-UT-G-2

APEX-FI for Industrial inspection solutions

Building 11 – Apartment 101 – Mahram Basha Compound – Mahram Bik – Alexandria – Egypt.

Phone: 002033683324

Mobile: 00201201585464

Fax: 002033682161

Email: info@apexfi.net

Web: www.apexfi.net

following us

Copyright@ APEXFI
Page load link
Login
Accessing this course requires a login. Please enter your credentials below!

Lost Your Password?
Go to Top