Quiz Summary
0 of 20 Questions completed
Questions:
Information
You must fill out this field. | |
, You must fill out this field. | |
You must fill out this field. |
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading…
You must sign in or sign up to start the quiz.
You must first complete the following:
Results
Results
Time has elapsed
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
- Current
- Review
- Answered
- Correct
- Incorrect
- Question 1 of 20
1. Question
The proper number of ampere-turns for a given test specimen is determined by:
- Question 2 of 20
2. Question
A circular field may be induced into a specimen by:
- Question 3 of 20
3. Question
In longitudinal magnetization, the proper term for calculating magnetizing force is:
- Question 4 of 20
4. Question
Why is it preferable to disassemble parts before magnetic particle inspection?
- Question 5 of 20
5. Question
Fluorescent magnetic particle indications should be inspected under:
- Question 6 of 20
6. Question
Welded plate of 25 mm thickness with prods, what minimum current shall be required to satisfactory inspection with prod spacing of 150 mm?
- Question 7 of 20
7. Question
What are the three causes of nonrelevant indications?
- Question 8 of 20
8. Question
A defect open to the surface produces an indication that is:
- Question 9 of 20
9. Question
What equipment is used to determine whether a part has been demagnetized?
- Question 10 of 20
10. Question
Why should parts be cleaned after demagnetization?
- Question 11 of 20
11. Question
The maximum spacing between prods for the best sensitivity is ________________________.
- Question 12 of 20
12. Question
An article has been circularly magnetized and retains a circular residual field. To replace the circular field with a longitudinal field, we longitudinally magnetize the article with a field that is as great or greater than:
- Question 13 of 20
13. Question
Whenever an article has been circularly magnetized, the first step in the demagnetization procedures is to establish:
- Question 14 of 20
14. Question
When a round steel bar is magnetized by passing alternating current through its length, flux density is:
- Question 15 of 20
15. Question
Surface seams in rolled bars are best detected in magnetic particle testing with:
- Question 16 of 20
16. Question
A test object 10 inches (25cm) long and 2 inches (5 cm) in diameter , longitudinally magnetized in a 5-turn coil, requires a magnetizing current of: (NI = 45 000 / (L/D))
- Question 17 of 20
17. Question
The only test method to use on articles made of soft steel with low retentivity is the ___________________ method.
- Question 18 of 20
18. Question
When defects have been removed from an article, or have been repaired, the next step is to _________________________ the article.
- Question 19 of 20
19. Question
When two pieces of steel rub against each other and either or both are in a magnetized condition, an indication is sometimes formed when magnetic particles are applied. This type of indications is called:
- Question 20 of 20
20. Question
When magnetizing with the central conductor, how many amperes would be required to circularly magnetize a hollow tube with an outside diameter of 2 inches (5 cm)?